IzolGlass Active TT film on glass
IzolGlass - Active TT film - datasheet Ver. 6 from 1 February 2026

The window stays. The parameters change.

Multi-layer 82 um PET film with a three-layer Active TT nano-coating. Applied to existing IGUs - without dismantling windows, without downtime and without losing interior brightness.

IzolGlass is a multilayer PET film with an Active TT nano-coating, spectrally selective - applied to existing double-glazed units. It blocks infrared (IR) and ultraviolet (UV) radiation while transmitting visible light. For offices, hospitals, storefronts and heritage buildings where window replacement is impossible or not permitted. Two variants:

Active TT South
maximum IR blocking
Active TT North
maximum light transmission
>94% IR blocking Datasheet Ver. 6
>99% UV blocking Datasheet Ver. 6
70-72% VLT - light transmission Datasheet Ver. 6
81% TSER at 60° angle Active TT South
0.000408 λ W/mK Journal of Thermal Analysis and Calorimetry 2024
NRO C-s1-d0 PN-EN 13501-1:2019-02

Glazing turns a building into a heat exchanger.

In summer

A glass facade lets infrared radiation through. HVAC works harder, but it does not remove the cause of overheating.

In winter

An IGU loses heat 4-6x faster than a wall of the same surface area.

In the project

Replacing joinery means PLN 2,000-4,000/m² and months of work. Film is applied to existing panes - 30-40 m²/day for a two-person crew.

Two variants of Active TT - choice by window orientation

Selection by exposure, package type and glass-edge condition. Active TT datasheet Ver. 6 from 1 February 2026.

Active TT South

Maximum protection against overheating. S, SE and SW exposures. Vertical windows.

>94% IR Active TT datasheet Ver. 6 from 1 February 2026
>99% UV Active TT datasheet Ver. 6 from 1 February 2026
70% VLT Active TT datasheet Ver. 6 from 1 February 2026
81% TSER Active TT datasheet Ver. 6 from 1 February 2026
Order a window audit

Active TT North

Universal, any solar exposure, priority on brightness and winter heat retention. Variant selection for skylights and roof windows - after a window audit.

>60% IR Active TT datasheet Ver. 6 from 1 February 2026
>99% UV Active TT datasheet Ver. 6 from 1 February 2026
72% VLT Active TT datasheet Ver. 6 from 1 February 2026
59% TSER Active TT datasheet Ver. 6 from 1 February 2026
Order a window audit

This is not a sun-control film.

Three things IzolGlass does not pretend to be.

It does not darken the interior as its main strategy.

VLT 70-72% means the window stays bright. The work happens in IR and UV, not by hiding daylight.

Active TT datasheet Ver. 6

It does not replace a window audit.

Every installation starts with an assessment of the package type, edge condition, exposure and frames. On low-E glass, the correct route may be IzolGlass Panel.

Variant selection procedure

It is not a mirror film.

Active TT does not create a mirror effect from the inside or outside. The selection is based on spectral parameters and the glass package audit - Active TT works at the nano-coating level.

Datasheet Ver. 6

A three-layer nano-coating on PET film.

Light stays. Heat and UV are controlled in the coating layer.

Cross-section: Active TT nanocoating on glass - visible light passes through, infrared is reflected, ultraviolet is blocked
1
2
3
4
  1. / 01 82 um PET film + Active TT

    Multi-layer 82 um PET film with a three-layer Active TT nano-coating. Applied to existing IGUs - without dismantling windows, without downtime and without losing interior brightness.

    Active TT datasheet Ver. 6 from 1 February 2026

  2. / 02 Visible light - passes through

    VLT 70% (South), 72% (North) - the window stays bright. The coating works in the IR and UV bands, it does not dim daylight.

    Active TT datasheet Ver. 6 from 1 February 2026

  3. / 03 Infrared - reflected

    The heat carrier. Active TT South reflects above 94% of IR - in summer the facade does not overheat the interior and the HVAC works less. The North variant blocks above 60% at any exposure.

    Active TT datasheet Ver. 6 from 1 February 2026

  4. / 04 Ultraviolet - blocked

    Active TT blocks above 99% of UV. Furniture, fabrics and interior finishes do not fade, and the window stays bright.

    Active TT datasheet Ver. 6 from 1 February 2026

Active TT datasheet Ver. 6 from 1 February 2026

/ Implementation

A glass facade without replacing IGUs.

Glass facade of an office building after IzolGlass audit
Wroclaw office building - implementation documentation
Glass facade before IzolGlass film application Before
HVAC works harder
PLN 2,000-4,000/m² joinery replacement
Glass facade after IzolGlass film application After
30-40 m²/day application
>94% IR Active TT South

The film is applied to existing panes - 30-40 m²/day for a two-person crew.

Active TT datasheet Ver. 6 from 1 February 2026

Active TT variant cards.

Both variants use the same application process. They differ by spectral performance and exposure.

/ 01 · ACTIVE TT SOUTH Ver. 6 · 1 February 2026

Active TT South

Maximum protection against overheating. S, SE and SW exposures. Vertical windows.

Active TT datasheet Ver. 6 from 1 February 2026

Technical parameters
IR
>94% Datasheet Ver. 6
UV
>99% Datasheet Ver. 6
VLT
70% Datasheet Ver. 6
TSER
81% 60° angle
Exposure
S, SE, SW
Application
Vertical windows
/ 02 · ACTIVE TT NORTH Ver. 6 · 1 February 2026

Active TT North

Universal, any solar exposure, priority on brightness and winter heat retention. Variant selection for skylights and roof windows - after a window audit.

Active TT datasheet Ver. 6 from 1 February 2026

Technical parameters
IR
>60% Datasheet Ver. 6
UV
>99% Datasheet Ver. 6
VLT
72% Datasheet Ver. 6
TSER
59% Datasheet Ver. 6
Exposure
Every solar exposure
Application
Universal, any solar exposure, priority on brightness and winter heat retention. Variant selection for skylights and roof windows - after a window audit.

Documents and parameter sources.

DOI, datasheet Ver. 6, variant selection procedure and classifications used in projects.

ACTIVE TT ACTIVE TT

Active TT (IzolGlass film)

Ver. 6 from 1 February 2026

Multi-layer 82 um PET film with a three-layer Active TT nano-coating. Applied to existing IGUs - without dismantling windows, without downtime and without losing interior brightness.

Active TT datasheet Ver. 6 from 1 February 2026

DOI DOI

Journal of Thermal Analysis and Calorimetry (Springer Nature), 2024

https://doi.org/10.1007/s10973-024-13673-9

Journal of Thermal Analysis and Calorimetry (Springer Nature) 2024 validates parameters of the previous transparent coating generation: λ 0.000408 W/mK, NIR 88.68%, UV 99.49%.

https://doi.org/10.1007/s10973-024-13673-9

Journal of Thermal Analysis and Calorimetry, 2024 - https://doi.org/10.1007/s10973-024-13673-9

PZH PZH

Adalio documents and approvals

Full registry on the Certificates page

Active TT film validation: Springer JTAC 2024 publication and datasheet Wer. 6 from 1 February 2026. Full set of PZH approvals, CE declarations, NRO fire classification and Adalio patents (for both product lines) - on the Certificates page.

Full documentation: /en/certifications

SELECTION SELECTION

Variant selection procedure

Package type, edge condition, exposure and frames

Every installation starts with an assessment of the package type, edge condition, exposure and frames. On low-E glass, the correct route may be IzolGlass Panel.

Variant selection procedure

/ Peer-reviewed publication

It has a peer-reviewed publication. Journal of Thermal Analysis and Calorimetry 2024 confirms parameters of the previous transparent coating generation: λ 0.000408 W/mK, NIR 88.68%, UV 99.49%.

Journal of Thermal Analysis and Calorimetry Springer Nature, 2024 DOI https://doi.org/10.1007/s10973-024-13673-9 Datasheet Ver. 6 Active TT from 1 February 2026
Open DOI

Application in three steps.

Calm form, concrete process.

  1. / 01

    Window audit and variant selection

    Measurement of glass area, assessment of package, exposure and frames. Result: free thermal audit, variant selection, measurement, ROI scenario, schedule.

  2. / 02

    Wet-method application

    Film mounted on the exterior side of the glass. Two-person crew: approx. 30-40 m²/day. Application only above +5°C (datasheet Ver. 6 from 1 February 2026).

  3. / 03

    Protocol and before/after measurement

    Thermography, product specification card, batch numbers, 5-year warranty. During the first 30 days - no window cleaning and no chemicals while the adhesive cross-links.

First variant selection. Then decision.

Measurement of glass area, assessment of package, exposure and frames. Result: free thermal audit, variant selection, measurement, ROI scenario and schedule.

Values are indicative. The audit gives concrete numbers for your building.

Next step

First measurement. Then decision.

B2B audit: thermography, building envelope assessment, variant selection, application scope, and an ROI scenario. We work with managers, engineers, and architects - whoever has to defend the decision.