Convection and conduction
Trapped gas or vacuum inside each microsphere eliminates air movement (thermos effect) and drastically lowers thermal conductivity. Measured coating λ: 0.00079 W/m·K.
MDPI Energies 2022 · DOI 10.3390/en15176286
Thin-film thermal-insulating coatings with polymer and ceramic microspheres. Applied to render, masonry, sheet metal, roofing felt, and industrial installations.
IzolPlus is six products that combine thermal insulation with thermal reflection in a layer under one millimetre. Applied by certified crews to roofs, walls and industrial installations since 2009. Three paints plus a primer, a render and a technical compound:
/ Reference measurement
Densely packed polymer microspheres block both fundamental heat transfer pathways.
Trapped gas or vacuum inside each microsphere eliminates air movement (thermos effect) and drastically lowers thermal conductivity. Measured coating λ: 0.00079 W/m·K.
MDPI Energies 2022 · DOI 10.3390/en15176286
Dense microsphere packing creates a thermo-reflective barrier. Coating reflectance >90% in the infrared band; façade measurement: TSR 93.32% across 250-2,500 nm.
Termo-Fasada datasheet
Reference: BIPLAN study (Katowice, 6 October 2014, G. Kaczmarzyk, Ph.D., Eng.).
Twin building, 0.4 m brick wall, no insulation. After double-sided IzolPlus (Termo-Fasada outside + Termo-Wnętrze inside), wall U-value dropped from 0.491 to 0.22 W/m²K. Gas consumption reduction in 2013/2014 heating season: 15-25%.
Each product is a separate technical document. Contact us directly for the datasheet.
Bitum datasheet
Termo-Fasada datasheet
PZH B.BK.60111.0396.2022
IzolPlus system
IzolPlus Tynk
GPEC/SEC expertise
For each sector: the problem to solve, product selection, evidence from a project and the next step.
Heat loss 4-6x faster through walls than assumed. Thermal bridges in corners.
Double-sided application (Termo-Wnętrze inside + Termo-Fasada outside)
Wall U-value 0.11-0.17 W/m²K. Thermal bridges eliminated. Payback 3-5 years.
BIPLAN 2014
No wet works allowed. Continuous operation required. Hygiene certificates.
IzolPlus Termo-Wnętrze - PZH covers hospitals. Phased work without shutdown.
Łazarski University 2022, Statistics Poland Archive 2016.
PZH certificate B.BK.60111.0396.2022
Felt/sheet metal roof reaches 71-86°C in summer, locally 102°C. HVAC overload. High cooling costs.
IzolPlus Bitum - spray application, two-layer. λ 0.0008 W/m·K, IR reflection >93%.
17-21°C in full sun after Bitum. >40°C difference vs uncoated roof.
AAM Driveline 2023
Conservation requires no shape change, vapor permeability, no EPS insulation.
Thin-film, vapor-permeable coating - compliant with conservation requirements.
Łapy parish church 2021. 1898 tenement house in Łomża (renovation 2023). Nadułki manor 2026.
Reference implementations
Steam piping at 99.8°C. Pipe surface 210°C. Energy losses, burn hazards.
TERMO STOP - mass for pipe, substation, valve insulation. 2 mm thickness.
GPEC Gdańsk: steam valve 210°C → 44°C. SEC Szczecin: energy gain >85%.
Expertise by A. Pawłowski, Ph.D., Eng.
/ Before / After
Before
After Datasheets, certificates, classifications, and publications used on this page.
Technical datasheet for IzolPlus Bitum. Confirms application method, recommended thickness, coverage, VOC, and fire classification NRO C-s1-d0.
Hygiene certificate for IZOLPLUS. Covers use inside public, industrial, and hospital buildings.
Reaction to fire classification according to PN-EN 13501-1:2019-02. Higher classes available on request.
CE declaration of conformity for organic-binder renders. Assessment system: 4. Notified body: 1487 (Łukasiewicz ICiMB Kraków).
Validation of the IzolPlus coating: TSR 86.95% across 250-2,500 nm, λ 0.00079 W/m·K. Hot-box method + CFD model.
Industrial insulation expertise for steam piping, substations, valves, and fittings. GPEC Gdańsk: steam valve 210°C → 44°C. SEC Szczecin: energy gain >85%.
B2B audit: thermography, envelope assessment, variant selection, application scope, ROI scenario.
Indicative values. A free thermal audit gives concrete numbers for your building.